Explore the most recent editions of MPO Magazine, featuring expert commentary, industry trends, and breakthrough technologies.
Access the full digital version of MPO Magazine anytime, anywhere, with interactive content and enhanced features.
Join our community of medical device professionals. Subscribe to MPO Magazine for the latest news and updates delivered straight to your mailbox.
Explore the transformative impact of additive manufacturing on medical devices, including design flexibility and materials.
Learn about outsourcing options in the medical device sector, focusing on quality, compliance, and operational excellence.
Stay updated on the latest electronic components and technologies driving innovation in medical devices.
Discover precision machining and laser processing solutions that enhance the quality and performance of medical devices.
Explore the latest materials and their applications in medical devices, focusing on performance, biocompatibility, and regulatory compliance.
Learn about advanced molding techniques for producing high-quality, complex medical device components.
Stay informed on best practices for packaging and sterilization methods that ensure product safety and compliance.
Explore the latest trends in research and development, as well as design innovations that drive the medical device industry forward.
Discover the role of software and IT solutions in enhancing the design, functionality, and security of medical devices.
Learn about the essential testing methods and standards that ensure the safety and effectiveness of medical devices.
Stay updated on innovations in tubing and extrusion processes for medical applications, focusing on precision and reliability.
Stay ahead with real-time updates on critical news affecting the medical device industry.
Access unique content and insights not available in the print edition of the MPO Magazine.
Explore feature articles that delve into specific topics within the medical device industry, providing in-depth analysis and insights.
Gain perspective from industry experts through regular columns addressing key challenges and innovations in medical devices.
Read the editor’s thoughts on the current state of the medical device industry.
Discover the leading companies in the medical device sector, showcasing their innovations and contributions to the industry.
Explore detailed profiles of medical device contract manufacturing and service provider companies, highlighting their capabilities and offerings.
Learn about the capabilities of medical device contract manufacturing and service provider companies, showcasing their expertise and resources.
Watch informative videos featuring industry leaders discussing trends, technologies, and insights in medical devices.
Short, engaging videos providing quick insights and updates on key topics within the medical device industry.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in the medical device sector.
Participate in informative webinars led by industry experts, covering various topics relevant to the medical device sector.
Stay informed on the latest press releases and announcements from leading companies in the medical device manufacturing industry.
Access comprehensive eBooks covering a range of topics on medical device manufacturing, design, and innovation.
Highlighting the innovators and entrepreneurs who are shaping the future of medical technology.
Explore sponsored articles and insights from leading companies in the medical device manufacturing sector.
Read in-depth whitepapers that explore key issues, trends, and research findings for the medical device industry.
Discover major industry events, trade shows, and conferences focused on medical devices and technology.
Get real-time updates and insights live from the CompaMed/Medica conference floor.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical devices.
Participate in the ODT Forum, focusing on orthopedic device trends and innovations.
Discover advertising opportunities with MPO to reach a targeted audience of medical device professionals.
Review our editorial guidelines for submissions and contributions to MPO.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of MPOmag.com.
What are you searching for?
HeartMate 3 is the first implantable mechanical heart pump, or LVAD, to use fully magnetic levitation technology.
March 12, 2018
By: American College of Cardiology
At two years of follow-up, severely ill patients with advanced heart failure who received a novel heart pump fully implantable within the chest experienced no malfunctions requiring replacement or removal of the device for blood clotting. Further, their risk of a stroke was halved compared with patients who received the established version of the pump that requires an abdominal location for the implant, according to research presented at the American College of Cardiology’s 67th Annual Scientific Session. The new device tested in this trial, the HeartMate 3, is the first implantable mechanical heart pump, or left ventricular assist device (LVAD), to use fully magnetic levitation technology—which makes the pump frictionless, or without mechanical bearings—to push blood through the device and into the aorta, the body’s central artery, said Mandeep R. Mehra, M.D., medical director of the Heart and Vascular Center, Brigham and Women’s Hospital in Boston and lead author of the study. “We saw a marked decrease in pump malfunction requiring reoperation, mostly driven by an absence of confirmed pump thrombosis, and a halving of observed stroke rates in patients implanted with the HeartMate 3 compared with patients who were implanted with the HeartMate II,” Mehra said. Although the trial was designed to show only that outcomes with the HeartMate 3 were no worse than those with the HeartMate II, the results demonstrate that outcomes are, in fact, clearly superior with the HeartMate 3 than with the standard device, he said. In advanced heart failure, the heart’s main pumping chamber, the left ventricle, is too weak to pump oxygen-rich blood from the lungs throughout the body. An LVAD is designed to supplement the pumping ability of the weakened heart in late-stage heart failure. It is implanted next to the heart and attached to the aorta, the main artery that sends blood to the rest of the body. The device is attached to and powered by an external battery pack worn by the patient. The trial, known as MOMENTUM-3, enrolled 1,028 patients at 69 centers in the U.S. Patients’ median age was 60 years and 78 percent were men. All had severe heart failure that left them unable to engage in any physical activity without discomfort. Most had symptoms of fatigue or shortness of breath even when resting. Most (85 percent) were receiving intravenous heart failure medication because pills alone no longer worked or caused intolerable adverse effects. Some patients in the study needed an LVAD to sustain them until they were able to receive a heart transplant. Others, because of age or other health problems, were not candidates for a transplant and relied on an LVAD as lifelong therapy. Patients were randomly assigned to be surgically implanted with either a HeartMate II or a HeartMate 3. All patients received blood-thinning medications following surgery. The primary study endpoint was the combined rate of disabling stroke, device malfunction requiring surgery to replace or remove it, and death from heart failure. Six-month outcomes for 294 patients were reported in the New England Journal of Medicine in November 2016. The current study reports outcomes for 366 patients who have completed two years of follow-up. A total of 82.8 percent of HeartMate 3 patients were alive at two years, compared with 76.2 percent of HeartMate II patients, Mehra said. One percent of HeartMate 3 patients needed additional surgery to remove or replace the device (due to an electrical or mechanical malfunction), compared with 17 percent of HeartMate II patients (two-thirds of which were for pump clotting). HeartMate 3 patients were also less likely to have a stroke, occurring in 10 percent vs. 19 percent of HeartMate II patients. However, the rate of disabling stroke—defined as a stroke resulting in severe inability to walk or attend to bodily needs without assistance—was not significantly different in the two groups of patients. “All of the benefit seen with the HeartMate 3 was in reducing the rate of nondisabling strokes,” Mehra said. “Disabling stroke was a low-frequency event—occurring in 5 to 7 percent of all patients in the trial. The overall stroke rate at two years is the lowest recorded to date in an LVAD trial.” One limitation of the current study is that it was impossible for either patients or their doctors to be blinded to which device was implanted, Mehra said. The lack of blinding could have led to differences in the way doctors managed patients who had received the HeartMate 3 compared with the HeartMate II. However, the trial was rigorously designed to prevent such differences from occurring, he said. Another potential limitation is that the surgical techniques for implanting the two devices are different. All centers participating in the study had considerable experience with the HeartMate II and all received the same training on how to implant the HeartMate 3. In addition to its use of magnetic levitation technology, the HeartMate 3 device has other design features that distinguish it from the HeartMate II, Mehra said. “First, the HeartMate 3 is small enough to be fully implanted in the chest, whereas the HeartMate II requires a ‘pocket’ to be created in the abdomen to accommodate the device,” he said. “Second, the blood-flow pathway is wider in the HeartMate 3, which may contribute to the reduction in pump thrombosis. Third, the HeartMate 3 is designed to speed up and slow down every two seconds, creating an artificial fixed pulse that may prevent blood from building up inside the device.” The HeartMate 3 received FDA approval on Aug. 31, 2017, for use in patients with advanced heart failure who are awaiting a heart transplant. Innovative features in the design of the MOMENTUM-3 trial made it possible to obtain initial FDA approval of the HeartMate 3 in under three years, Mehra said, in contrast to the approximately seven years that this process has typically taken in the past. Among these innovations is the decision to enroll patients whether or not they were candidates for a heart transplant, he said. In the past, an initial trial would have assessed the safety of the device, a second trial would have tested it in patients awaiting a heart transplant and a third trial would have examined patients ineligible for a transplant. Two-year follow-up results for all 1,028 patients enrolled in the trial are expected by late 2019, he said. The study was funded by Abbott Inc.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !