Explore the most recent editions of MPO Magazine, featuring expert commentary, industry trends, and breakthrough technologies.
Access the full digital version of MPO Magazine anytime, anywhere, with interactive content and enhanced features.
Join our community of medical device professionals. Subscribe to MPO Magazine for the latest news and updates delivered straight to your mailbox.
Explore the transformative impact of additive manufacturing on medical devices, including design flexibility and materials.
Learn about outsourcing options in the medical device sector, focusing on quality, compliance, and operational excellence.
Stay updated on the latest electronic components and technologies driving innovation in medical devices.
Discover precision machining and laser processing solutions that enhance the quality and performance of medical devices.
Explore the latest materials and their applications in medical devices, focusing on performance, biocompatibility, and regulatory compliance.
Learn about advanced molding techniques for producing high-quality, complex medical device components.
Stay informed on best practices for packaging and sterilization methods that ensure product safety and compliance.
Explore the latest trends in research and development, as well as design innovations that drive the medical device industry forward.
Discover the role of software and IT solutions in enhancing the design, functionality, and security of medical devices.
Learn about the essential testing methods and standards that ensure the safety and effectiveness of medical devices.
Stay updated on innovations in tubing and extrusion processes for medical applications, focusing on precision and reliability.
Stay ahead with real-time updates on critical news affecting the medical device industry.
Access unique content and insights not available in the print edition of the MPO Magazine.
Explore feature articles that delve into specific topics within the medical device industry, providing in-depth analysis and insights.
Gain perspective from industry experts through regular columns addressing key challenges and innovations in medical devices.
Read the editor’s thoughts on the current state of the medical device industry.
Discover the leading companies in the medical device sector, showcasing their innovations and contributions to the industry.
Explore detailed profiles of medical device contract manufacturing and service provider companies, highlighting their capabilities and offerings.
Learn about the capabilities of medical device contract manufacturing and service provider companies, showcasing their expertise and resources.
Watch informative videos featuring industry leaders discussing trends, technologies, and insights in medical devices.
Short, engaging videos providing quick insights and updates on key topics within the medical device industry.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in the medical device sector.
Participate in informative webinars led by industry experts, covering various topics relevant to the medical device sector.
Stay informed on the latest press releases and announcements from leading companies in the medical device manufacturing industry.
Access comprehensive eBooks covering a range of topics on medical device manufacturing, design, and innovation.
Highlighting the innovators and entrepreneurs who are shaping the future of medical technology.
Explore sponsored articles and insights from leading companies in the medical device manufacturing sector.
Read in-depth whitepapers that explore key issues, trends, and research findings for the medical device industry.
Discover major industry events, trade shows, and conferences focused on medical devices and technology.
Get real-time updates and insights live from the CompaMed/Medica conference floor.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical devices.
Participate in the ODT Forum, focusing on orthopedic device trends and innovations.
Discover advertising opportunities with MPO to reach a targeted audience of medical device professionals.
Review our editorial guidelines for submissions and contributions to MPO.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of MPOmag.com.
What are you searching for?
Solution impregnation of antibiotics imparts microbial resistance to silicone components.
February 3, 2016
By: Mark Paulsen
Contributing Writer
The costs of hospital-acquired infection (HAI) are staggering. A 2009 report1 published by the Centers for Disease Control (CDC) estimated the annual national direct medical costs of HAI to range between $28.4 billion and $45 billion, and notes that approximately 20 percent of all HAIs are preventable based on current medical technology. The CDC report, citing previous studies, distinguishes device-related infection (DRI) from other vectors, noting for example, that 37 percent of bloodstream infections and 80 percent of urinary tract infections are device related. Another report2 notes more generally that more than half of HAIs are attributed to medical devices such as central venous catheters, endotracheal tubes, bladder catheters, and various surgical implants. Silicone elastomers are in many ways an ideal biomaterial. These elastomers can be fabricated using standardized processes to produce tubing, coatings, thin membranes, and various other types of molded components. Silicones enjoy a 60-year history as an implant material and represent the gold standard for biocompatibility and biostability. Silicones are not, however, immune to bacterial colonization. Like other hydrophobic materials, the surface of silicone medical devices allow attachment and adhesion of various micoorganisms.3 Various techniques have been investigated to minimize the attachment of bacteria to the surface of silicone medical devices and hence to reduce the incidence of surgical site (SSI) and bloodstream infection (BSI). Coatings, often containing silver-based compounds, have shown to be effective at reducing the population of certain types of bacteria. Coating processes have several drawbacks, though. The process often involves costly automated spraying or dipping equipment; analytical techniques must be developed to measure coat weight uniformity; the durability of the coating and adhesion to the silicone substrate must be proven under different conditions; and the antimicrobial efficacy of the thin coating is often of limited duration. Additionally, in the case of catheters, most coating processes cannot treat the surface of the inner lumen. A second approach involves the addition of antibiotic active pharmaceutical ingredients (API) to silicone raw materials. Specialty Silicone Fabricators’ (SSF) lab has previously worked with several antibiotic drugs including chlorhexidine, gentamycin, xifaxin and doxycycline. In all cases, the drugs, in powder form, were combined with different silicones using numerous types of mixing equipment. After homogenization, these silicone-drug mixtures can be formed into desired shapes and vulcanized using various fabrication processes. But this process also suffers limitations. It is known that some API will inhibit or poison the cure system of certain silicones. Also, many drugs are unstable at the elevated temperatures required for the cost-effective vulcanization of silicone components. The development of robust mixing processes often involve numerous trial iterations using highly specialized equipment. Analytical test methods must be developed to confirm the homogeneity of the drug within a mix-batch. The qualification and validation of mixing processes is performed using production-ready equipment as batch sizes are typically large and drug costs can be considerable. The particle size of the drug powder is an important variable as it affects release kinetics from the finished component. Particle size, therefore, must be maintained within a narrow window despite the tendency of many drug powders to agglomerate during storage. Finally, post-manufacturing cleaning processes must be developed and validated to ensure that drug-contacting surfaces of both mixing and fabrication equipment are within API carry-over limits. The work described below provides an alternative approach to manufacturing antimicrobial silicone device components that offers considerable advantages over traditional processes. Study Methodology The vast majority of silicone medical components are manufactured from raw material formulations containing polydimethylsiloxane (PDMS) polymers reinforced with amorphous non-crystalline silica. It is known that vulcanized PDMS elastomers easily swell when immersed in various organic solvents. SSF’s study investigated the simultaneous transfer of two drugs from solution into pre-vulcanized silicone rubber components. The two antibiotic API investigated were Clindamycin Hydrochloride (CLIN)—mol weight = 461.45 g/mol—and Rifampicin (RIF)—mol weight = 822.94 g/mol. Study variables included 1) the total concentration of the drugs in solution; 2) the ratio of the drugs in solution; 3) immersion time of the silicone component; and 4) the durometer of the silicone test article. Effect of Solution Concentration on Drug Impregnation CLIN and RIF were added to chloroform to produce three unique solutions. The CLIN/RIF ratio was held constant but the overall concentration of the two drugs in solution was varied from x to 2x to 10x. Six-inch lengths of silicone tubing (50 durometer Shore A) were immersed in the solutions. Tubes were removed from solution at predetermined intervals; immersion times ranged from a few minutes to several hours. The impregnated tubing was then blotted dry and the inner lumen flushed with IPA. The test articles were then allowed to devolatilize for 24 hours. SSF’s analytical lab developed methodology to extract both drugs from the silicone test articles as well as HPLC test methods to quantify drug concentrations. Small sections of tubes were weighed and extracted. The extract was then evaluated via HPLC to determine the masses of both drugs within a known mass of tubing. Results for the drug content testing of both CLIN and RIF are expressed in the units of micrograms of drug per gram of tube. Data for tubing immersed in the three different solutions is summarized in Figure 1. Five data points, representing different immersion times, are plotted for each of the three solutions. In general, as the concentration of API in solution increased, so too did the resultant concentration within the silicone test article. It’s also evident from the plotted data that the rate of impregnation is strongly influenced by the concentration of the immersion solution. Finally, the lines representing the three data sets have similar slopes, indicating that the ratio of the two drugs impregnated within the silicone is dependent on the ratio of the drugs in solution and largely independent of the overall solution concentration. Impact of Silicone on Drug Impregnation A second experiment investigated the impact of elastomer formulation on both the mass transfer of the drugs from solution as well as the rate of impregnation. CLIN and RIF were added to chloroform to produce a 2x solution identical to that discussed in the previous test. Short lengths of 20 and 80 durometer tubing were immersed and then removed at the same five-time intervals as the prior experiment. Tubing segments were again assayed for total drug content. Durometer is a measure of hardness. In general, in silica-reinforced systems such as the materials used in this study, an increase in durometer is mirrored by an increase in the silica content of the rubber. Approximate densities of silica and PDMS polymers are 2.2 and 1.0 g/cc, respectively. The specific gravity values for silicone elastomers provides a convenient means for quantifying and comparing the silica-polymer ratio between different rubbers. Specific gravities of the 20, 50, and 80 durometer tubes investigated here were 1.10, 1.16, and 1.21, respectively. In this regard, durometer was used as a proxy for polymer concentration within the rubber. SSF study investigators hypothesized that the quasi-organic PDMS polymer, relative to the inorganic silica, would be more readily swelled by halogenated-organic solvents and the mass and rate of drug transfer would therefore increase as durometer decreased. Results are summarized in Figure 2. Twenty durometer tubes, with high polymer content, absorbed more Clindamycin and at a faster rate than the 50 durometer tubes containing less polymer. Somewhat surprisingly, the mass and impregnation rate of rifampicin in the 20 durometer tubes was lower than that observed in the 50 durometer samples. Both API were below test detection limits in the 80 durometer tubes. Varying API Ratios, Impact on Impregnation A third experiment investigated how changes in the ratio of the two drugs in solution impacted drug concentrations in the silicone elastomer. It is known that some types of ventricular catheters, a key component of life-saving hydrocephalus shunts, contain CLIN and RIF, and that studies have confirmed the antimicrobial efficacy of these devices. The literature does not address the manufacturing method used to produce these products but it does provide detailed information about the target concentrations of both drugs as well as specification ranges. Labeling for the devices notes CLIN and RIF concentrations of 0.15 percent (wt/wt) and 0.054 percent, respectively. Supporting literature discusses a specification ranges of ±45 percent for CLIN and 60 percent for RIF. These drug concentrations and ranges were used as targets in this experiment. Several solutions were prepared in which the concentrations of CLIN and RIF were adjusted from the 1:1 ratio used in the previous experiments. As in the earlier tests, a number of immersion times were investigated for each of the solutions. Results are shown in Figure 3. The target concentration for both API is shown here as the white circle while the specification ranges for the drugs (RIF = 216-864, CLIN = 825-2,195) are identified as the area within the white box. Experimental results showed that several immersion times in two different solutions resulted in tubing drug concentrations that were within the specification range and that two data points (circled green) were very close to the published API target of the predicate devices. Bacterial Challenge—Antimicrobial Efficacy Confirmed The immersion experiments discussed previously demonstrated conclusively the mass transfer of both drugs from solution to the silicone tubing. Additionally, it was shown that the masses of drugs impregnated within the tubing were dependent upon controllable factors including solution concentration, immersion duration, and silicone type. Importantly, though, the correlation between drug contents within the silicone and antimicrobial efficacy remained undetermined. SSF study investigators commissioned a Kirby-Bauer Zone of Inhibition (ZOI) test to assess the impact of drug content on the gram-positive coccal bacterium, Staphylococcus aureus. Staph aureus is responsible for particularly high incidence rates of HAI and DRI. In a technical brief,4 the National Institute of Allergy and Infectious Disease (NIAID) notes that each year an estimated 500,000 patients contract staph infections in American hospitals and that “S. aureus is the most common cause of HAI.” Other researchers note that “infections associated with indwelling medical devices ranging from simple intravenous catheters to prosthetic joints and replacement heart valves can be caused by S. aureus.”5 Test articles were chosen so that antimicrobial efficacy could be evaluated across a range of samples produced under varying conditions and containing different drug concentrations. Immersion conditions and drug content are summarized in Table 1. The three test articles were placed on an agar plate that had been inoculated with a suspension containing Staphylococcus aureas. The plate was photographed after a 24 hour incubation period and is depicted in Figure 4. The drug-impregnated tubing had a powerful inhibitory effect on the growth of S. aureus and clear zones of inhibition are seen surrounding test articles B and C. As expected, the higher drug concentrations in sample C produced a larger ZOI (18 mm) than sample B (14 mm), which contained lower concentrations of both drugs. No ZOI was observed around the control sample. Discussion Attractive forces between silicone polymer chains are quite weak. This contributes to the characteristic high free volume of silicone elastomers and their exceptional permeability. In turn, the high permeability of silicone rubber makes this biomaterial especially attractive as a matrix for drug-device combination products. As noted, the process for manufacturing most silicone drug-device components involves adding a drug powder to a silicone raw material, forming the mixture into a desired shape, then vulcanizing at elevated temperatures. But as discussed, there are several inherent concerns with this process that add complexity and costs. Advantages of Immersion/Impregnation The immersion/impregnation processes presented in these experiments offer several important advantages over current silicone drug-device manufacturing methods. These advantages include the following:
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !