Explore the most recent editions of MPO Magazine, featuring expert commentary, industry trends, and breakthrough technologies.
Access the full digital version of MPO Magazine anytime, anywhere, with interactive content and enhanced features.
Join our community of medical device professionals. Subscribe to MPO Magazine for the latest news and updates delivered straight to your mailbox.
Explore the transformative impact of additive manufacturing on medical devices, including design flexibility and materials.
Learn about outsourcing options in the medical device sector, focusing on quality, compliance, and operational excellence.
Stay updated on the latest electronic components and technologies driving innovation in medical devices.
Discover precision machining and laser processing solutions that enhance the quality and performance of medical devices.
Explore the latest materials and their applications in medical devices, focusing on performance, biocompatibility, and regulatory compliance.
Learn about advanced molding techniques for producing high-quality, complex medical device components.
Stay informed on best practices for packaging and sterilization methods that ensure product safety and compliance.
Explore the latest trends in research and development, as well as design innovations that drive the medical device industry forward.
Discover the role of software and IT solutions in enhancing the design, functionality, and security of medical devices.
Learn about the essential testing methods and standards that ensure the safety and effectiveness of medical devices.
Stay updated on innovations in tubing and extrusion processes for medical applications, focusing on precision and reliability.
Stay ahead with real-time updates on critical news affecting the medical device industry.
Access unique content and insights not available in the print edition of the MPO Magazine.
Explore feature articles that delve into specific topics within the medical device industry, providing in-depth analysis and insights.
Gain perspective from industry experts through regular columns addressing key challenges and innovations in medical devices.
Read the editor’s thoughts on the current state of the medical device industry.
Discover the leading companies in the medical device sector, showcasing their innovations and contributions to the industry.
Explore detailed profiles of medical device contract manufacturing and service provider companies, highlighting their capabilities and offerings.
Learn about the capabilities of medical device contract manufacturing and service provider companies, showcasing their expertise and resources.
Watch informative videos featuring industry leaders discussing trends, technologies, and insights in medical devices.
Short, engaging videos providing quick insights and updates on key topics within the medical device industry.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in the medical device sector.
Participate in informative webinars led by industry experts, covering various topics relevant to the medical device sector.
Stay informed on the latest press releases and announcements from leading companies in the medical device manufacturing industry.
Access comprehensive eBooks covering a range of topics on medical device manufacturing, design, and innovation.
Highlighting the innovators and entrepreneurs who are shaping the future of medical technology.
Explore sponsored articles and insights from leading companies in the medical device manufacturing sector.
Read in-depth whitepapers that explore key issues, trends, and research findings for the medical device industry.
Discover major industry events, trade shows, and conferences focused on medical devices and technology.
Get real-time updates and insights live from the CompaMed/Medica conference floor.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical devices.
Participate in the ODT Forum, focusing on orthopedic device trends and innovations.
Discover advertising opportunities with MPO to reach a targeted audience of medical device professionals.
Review our editorial guidelines for submissions and contributions to MPO.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of MPOmag.com.
What are you searching for?
Measurements could help scientists develop better designs for a bioartificial pancreas.
February 26, 2019
By: Anne Trafton
MIT News Office
Transplanting pancreatic islet cells into patients with diabetes is a promising alternative to the daily insulin injections that many of these patients now require. These cells could act as a bioartificial pancreas, monitoring blood glucose levels and secreting insulin when needed. For this kind of transplantation to be successful, scientists need to make sure that the implanted cells receive enough oxygen, which they need in order to produce insulin and to remain viable. MIT engineers have now devised a way to measure oxygen levels of these cells over long periods of time in living animals, which should help them predict which implants will be most effective. In a paper appearing in the Proceedings of the National Academy of Sciences the week of Feb. 25, the researchers demonstrated that they could use this method, a specialized type of magnetic resonance imaging (MRI), to track how oxygen levels of implanted cells in the intraperitoneal (IP) cavity of mice change as they move through the cavity over a prolonged period of time. “Our goal is to make living cellular factories that can supply drugs on demand for patients. The ability to track the oxygen supply and the location of implanted cells will help us better understand how to build and use successful therapies,” said Daniel Anderson, an associate professor in MIT’s Department of Chemical Engineering, a member of MIT’s Koch Institute for Integrative Cancer Research and Institute for Medical Engineering and Science (IMES), and the senior author of the study. Virginia Spanoudaki, the scientific director of the Koch Institute Animal Imaging and Preclinical Testing Core Facility, is the lead author of the study. Other authors include MIT postdocs Joshua Doloff and Shady Farah, research scientist Wei Huang, former research affiliate Samuel Norcross, and David H. Koch Institute Professor Robert Langer. Better Measurements For the past several years, Anderson, Langer, and their colleagues have been developing implantable islet cells encapsulated in particles made of alginate, a starchy molecule naturally found in algae. Such particles could be used to replace the pancreatic islet cells of people with Type 1 diabetes, which do not function properly. In an earlier study, the researchers found that larger particles, with a diameter of 1.5 millimeters, maintain their function longer than smaller particles (0.5-millimeter diameter), in part because the smaller particles tend to become surrounded by scar tissue, which blocks their access to oxygen. However, questions still remained about the role of oxygen in the fate of these implanted cells. The particles can move through the IP space once implanted, which makes tracking them and their oxygen exposure important. Different parts of the IP space contain varying levels of oxygen, and previous studies had shown that the smaller particles tend to cluster in patches of fat, which have less oxygen, contributing to their failure. Optical microsensors that are typically used for measuring oxygen levels in living tissue are very fragile and invasive, so the MIT team decided to try an alternative approach: fluorine MRI, a previously developed technique that other researchers have used to track living cells. While traditional MRI measures interactions between a magnetic field and hydrogen nuclei, fluorine MRI can measure similar interactions between a magnetic field and fluorine nuclei, as well as how these interactions are affected by the presence of oxygen. To perform the study, the researchers incorporated a fluorine-containing material called a perfluorocarbon emulsion into the alginate that they normally use to encapsulate their islet cells. They tested particles with diameters of 0.5 and 1.5 millimeters, in both diabetic and nondiabetic mice. The nondiabetic mice received alginate implants with no cells inside, while the diabetic mice received implants with pancreatic islet cells. The researchers then used fluorine MRI to measure oxygen levels in the IP space over a three-month period. At the same time, they also measured the diabetic mice’s blood glucose levels. To help them analyze the resulting data, the researchers used a machine-learning algorithm to go through all of the images and find associations between the positions of the capsules within the IP space, the oxygen levels, and the blood glucose levels of the mice. “These kinds of imaging studies involve a lot of data, and screening all of these 2D images and making decisions about how the position of the capsules affects oxygen concentration is extremely challenging and very error prone when it’s done by a human observer,” Spanoudaki said. “So we relied on machine learning to automatically go through the images and find associations between the positions of the capsules and other parameters.” This analysis revealed that the smaller capsules produce enough insulin to treat diabetic mice during the first 30 days of treatment, but then tend to organize in large clusters and accumulate in the fatty areas of the animals’ extremities. Once the particles become stuck in these oxygen-deprived regions, blood glucose levels rise in the mice. The larger capsules tended to spread out over a larger area so that some ended up in low-oxygen areas and others in high-oxygen areas. Overall, the cells secreted enough insulin to keep the diabetic mice’s blood glucose levels stable over several months. Gordon Weir, the co-head of the Joslin Diabetes Center’s section on islet and regenerative biology, said the study sheds light on important issues regarding the optimal size of the alginate capsules used to deliver islet cells. “The MIT group has previously shown the better transplant results in mice (and non-human primates) using capsules with a diameter of 1.5 millimeters compared with 0.5 millimeters,” said Weir, who was not involved in the research. “Now with this remarkable technique, we can see what we suspected: that the smaller capsules tend to clump more easily, which results in a more hypoxic environment that leads to impaired insulin secretion and more cell death.” Toward a Bioartificial Pancreas Sigilon Therapeutics, a company started by Langer, Anderson, and others to further develop the bioartificial pancreas, hopes to begin testing implantable islet cells in patients early next year, Anderson said. The new oxygen measurement technique could potentially be adapted for use in larger animals, including humans, which could help guide the development of future versions of the encapsulated islets, the researchers said. “Based on measurements in larger animals, we would like to understand whether there are different ways to design the bioartificial pancreas so that this aggregation of capsules that potentially results in reduced oxygen does not happen,” Spanoudaki said. “We are hoping to use this as a guide to make better designs for the bioartificial pancreas.” The researchers are also hoping to adapt the fluorine MRI technology to study how oxygen levels affect other kinds of cell processes such as metastasis and immune cell activation.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !