Explore the most recent editions of MPO Magazine, featuring expert commentary, industry trends, and breakthrough technologies.
Access the full digital version of MPO Magazine anytime, anywhere, with interactive content and enhanced features.
Join our community of medical device professionals. Subscribe to MPO Magazine for the latest news and updates delivered straight to your mailbox.
Explore the transformative impact of additive manufacturing on medical devices, including design flexibility and materials.
Learn about outsourcing options in the medical device sector, focusing on quality, compliance, and operational excellence.
Stay updated on the latest electronic components and technologies driving innovation in medical devices.
Discover precision machining and laser processing solutions that enhance the quality and performance of medical devices.
Explore the latest materials and their applications in medical devices, focusing on performance, biocompatibility, and regulatory compliance.
Learn about advanced molding techniques for producing high-quality, complex medical device components.
Stay informed on best practices for packaging and sterilization methods that ensure product safety and compliance.
Explore the latest trends in research and development, as well as design innovations that drive the medical device industry forward.
Discover the role of software and IT solutions in enhancing the design, functionality, and security of medical devices.
Learn about the essential testing methods and standards that ensure the safety and effectiveness of medical devices.
Stay updated on innovations in tubing and extrusion processes for medical applications, focusing on precision and reliability.
Stay ahead with real-time updates on critical news affecting the medical device industry.
Access unique content and insights not available in the print edition of the MPO Magazine.
Explore feature articles that delve into specific topics within the medical device industry, providing in-depth analysis and insights.
Gain perspective from industry experts through regular columns addressing key challenges and innovations in medical devices.
Read the editor’s thoughts on the current state of the medical device industry.
Discover the leading companies in the medical device sector, showcasing their innovations and contributions to the industry.
Explore detailed profiles of medical device contract manufacturing and service provider companies, highlighting their capabilities and offerings.
Learn about the capabilities of medical device contract manufacturing and service provider companies, showcasing their expertise and resources.
Watch informative videos featuring industry leaders discussing trends, technologies, and insights in medical devices.
Short, engaging videos providing quick insights and updates on key topics within the medical device industry.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in the medical device sector.
Participate in informative webinars led by industry experts, covering various topics relevant to the medical device sector.
Stay informed on the latest press releases and announcements from leading companies in the medical device manufacturing industry.
Access comprehensive eBooks covering a range of topics on medical device manufacturing, design, and innovation.
Highlighting the innovators and entrepreneurs who are shaping the future of medical technology.
Explore sponsored articles and insights from leading companies in the medical device manufacturing sector.
Read in-depth whitepapers that explore key issues, trends, and research findings for the medical device industry.
Discover major industry events, trade shows, and conferences focused on medical devices and technology.
Get real-time updates and insights live from the CompaMed/Medica conference floor.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical devices.
Participate in the ODT Forum, focusing on orthopedic device trends and innovations.
Discover advertising opportunities with MPO to reach a targeted audience of medical device professionals.
Review our editorial guidelines for submissions and contributions to MPO.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of MPOmag.com.
What are you searching for?
Compact handheld probe can be used for microscopic analysis of tissue without any special stains or preparation.
April 28, 2017
By: The Optical Society
In an important step toward endoscopic diagnosis of cancer, researchers have developed a handheld fiber optic probe that can be used to perform multiple nonlinear imaging techniques without the need for tissue staining. The new multimodal imaging probe uses an ultrafast laser to create nonlinear optical effects in tissue that can reveal cancer and other diseases. Today, cancer is typically diagnosed by removing a bit of tissue with a biopsy and then sending that tissue to a specially trained pathologist who stains the tissue and uses a microscope to look for cancerous cells. The ability for doctors to skip the biopsy and use a multimodal imaging endoscope to diagnose cancer on the spot would save valuable time and could also allow surgeons to more easily differentiate between cancerous and healthy tissue during surgery. With the new probe, imaging techniques that previously required bulky table-top instruments can be performed with a handheld device measuring only 8 millimeters in diameter, about the same diameter as a ballpoint pen. If miniaturized further, the probe could easily be integrated into an endoscope for nonlinear multimodal imaging inside the body. “We hope that, one day, multimodal endoscopic imaging techniques could help doctors make quick decisions during surgery, without the need for taking biopsies, using staining treatments or performing complex histopathological procedures,” said Jürgen Popp, from Leibniz Institute of Photonic Technology in Jena, Germany and the paper’s lead author. The researchers detail their new handheld probe in Optica, The Optical Society’s journal for high impact research. It is the first miniaturized probe for multimodal biological imaging to incorporate a multicore imaging fiber, a type of optical fiber consisting of several thousand light-guiding elements. This special imaging fiber allowed the researchers to keep all moving parts and electric power outside of the probe head, making the probe easy and safe to use in the body. The researchers have tested the probe with many types of tissue samples, but because it is currently designed for forward view mode, the primary applications of the probe would likely include skin, brain or head and neck surgery. They are working on implementing a side view mode that could be used to investigate hollow organs and arteries such as the colon, bladder or aorta. A Mini Microscope “The new probe serves as a miniaturized microscope that uses near-infrared lasers to investigate tissue,” said Popp. “Different components of biological tissue react differently to the excitation lasers, and their unique response gives us information about the molecular composition and morphology within the tissue.” The handheld multimodal imaging probe can simultaneously acquire several types of images: coherent anti-stokes Raman scattering, second harmonic generation and two-photon excited auto-fluorescence. These nonlinear imaging techniques have been shown to be useful for clinical diagnostics, including identifying cancerous cells, but it has been difficult to miniaturize the required instrumentation for use inside the body. The probe’s reduced size comes from its use of gradient index, or GRIN, lenses to focus the laser light. Compared to traditional spherical lenses that use complicated shaped surfaces to focus light, GRIN lenses can be made very small because they focus light through continuous refractive index changes within the lens material. Popp’s research team collaborated with scientists from Grintech Gmbh who designed GRIN lenses only 1.8 millimeters in diameter and helped incorporate the robust lens assembly into a small aluminum housing. Endoscopes designed for nonlinear imaging commonly use moving mirrors and electromechanical devices for point by point laser scanning in the probe head. Using the multicore imaging fiber allowed the researchers to further reduce the device’s size by moving the laser scanning out of the probe head and away from the sample site. Because the fiber’s thousands of light guiding elements, or cores, preserve the spatial relationship of the light between the two ends of the fiber, the scanning can be performed at the opposite end of the fiber, making an endoscopic approach much easier. “Compared to other endoscopic nonlinear imaging approaches, our fiber probe stands out due to its simplicity,” said Popp. “Since no moving parts are incorporated in the probe head, possible misalignments in the optics are limited and the probe’s overall lifetime is increased.” Multimodal Imaging of Tissue The researchers demonstrated the unique capabilities of the multicore imaging fiber by moving one end of the probe across a sample and transferring the acquired images to the other end. “This is not a trivial task since the cores of the imaging fiber differ in size and shape, hindering efficient and homogeneous coupling of the excitation lasers,” said Popp. “Furthermore, we had to deal with unwanted effects like different wavelengths interacting inside the fiber and core-to-core light coupling.” They also demonstrated that the probe could acquire separate coherent anti-stokes Raman scattering, second harmonic generation and two-photon excited autofluorescence images of healthy human skin tissue samples with a resolution of 2048 by 2048 pixels for a scanned area of 300 by 300 microns. This resolution and field of view is sufficient for identifying tumor borders, and the probe can be moved over the tissue surface to get an overview of the affected area. The researchers are working to use algorithms to improve the quality of the multimodal images, which appear pixelated because of the structure of the multicore imaging fiber. As a next step, they plan to test the probe in animal models and with patients in a clinical setting. Find more information on the study here.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !