Explore the most recent editions of MPO Magazine, featuring expert commentary, industry trends, and breakthrough technologies.
Access the full digital version of MPO Magazine anytime, anywhere, with interactive content and enhanced features.
Join our community of medical device professionals. Subscribe to MPO Magazine for the latest news and updates delivered straight to your mailbox.
Explore the transformative impact of additive manufacturing on medical devices, including design flexibility and materials.
Learn about outsourcing options in the medical device sector, focusing on quality, compliance, and operational excellence.
Stay updated on the latest electronic components and technologies driving innovation in medical devices.
Discover precision machining and laser processing solutions that enhance the quality and performance of medical devices.
Explore the latest materials and their applications in medical devices, focusing on performance, biocompatibility, and regulatory compliance.
Learn about advanced molding techniques for producing high-quality, complex medical device components.
Stay informed on best practices for packaging and sterilization methods that ensure product safety and compliance.
Explore the latest trends in research and development, as well as design innovations that drive the medical device industry forward.
Discover the role of software and IT solutions in enhancing the design, functionality, and security of medical devices.
Learn about the essential testing methods and standards that ensure the safety and effectiveness of medical devices.
Stay updated on innovations in tubing and extrusion processes for medical applications, focusing on precision and reliability.
Stay ahead with real-time updates on critical news affecting the medical device industry.
Access unique content and insights not available in the print edition of the MPO Magazine.
Explore feature articles that delve into specific topics within the medical device industry, providing in-depth analysis and insights.
Gain perspective from industry experts through regular columns addressing key challenges and innovations in medical devices.
Read the editor’s thoughts on the current state of the medical device industry.
Discover the leading companies in the medical device sector, showcasing their innovations and contributions to the industry.
Explore detailed profiles of medical device contract manufacturing and service provider companies, highlighting their capabilities and offerings.
Learn about the capabilities of medical device contract manufacturing and service provider companies, showcasing their expertise and resources.
Watch informative videos featuring industry leaders discussing trends, technologies, and insights in medical devices.
Short, engaging videos providing quick insights and updates on key topics within the medical device industry.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in the medical device sector.
Participate in informative webinars led by industry experts, covering various topics relevant to the medical device sector.
Stay informed on the latest press releases and announcements from leading companies in the medical device manufacturing industry.
Access comprehensive eBooks covering a range of topics on medical device manufacturing, design, and innovation.
Highlighting the innovators and entrepreneurs who are shaping the future of medical technology.
Explore sponsored articles and insights from leading companies in the medical device manufacturing sector.
Read in-depth whitepapers that explore key issues, trends, and research findings for the medical device industry.
Discover major industry events, trade shows, and conferences focused on medical devices and technology.
Get real-time updates and insights live from the CompaMed/Medica conference floor.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical devices.
Participate in the ODT Forum, focusing on orthopedic device trends and innovations.
Discover advertising opportunities with MPO to reach a targeted audience of medical device professionals.
Review our editorial guidelines for submissions and contributions to MPO.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of MPOmag.com.
What are you searching for?
Advanced signal analysis algorithms evaluate properties of acoustic signals passing through brain to determine ICP values.
Researchers from Klinikum Stuttgart and the University of Erlangen, Germany, report preliminary findings that show a noninvasive method of monitoring intracranial pressure (ICP) that could rival the gold standards of invasive intraventricular and intraparenchymal monitoring. To date no noninvasive method of ICP monitoring has proved adequate to replace invasive ones. The new noninvasive monitoring device uses advanced signal analysis algorithms to evaluate properties of acoustic signals that pass through the brain in order to determine ICP values. It is described in the article “Evaluation of a novel noninvasive ICP monitoring device in patients undergoing invasive ICP monitoring: preliminary results,” by Oliver Ganslandt, M.D., and colleagues. Background. Normally human intracranial pressure (ICP) is 20 mm Hg or lower, but in the presence of brain disease or traumatic head injury, brain tissues may swell or cerebrospinal fluid—the liquid that surrounds and protects the brain—may increase in volume, causing ICP to increase. Increased ICP can cause serious symptoms and sometimes even death. Continuous monitoring of ICP in critical-care patients provides clinicians with the knowledge of whether and when action must be taken to decrease ICP. To perform invasive ICP monitoring a hole must first be drilled in the patient’s skull. A catheter is then inserted into brain tissue (parenchyma) or into a ventricle (a space within the brain that contains cerebrospinal fluid). Sensors in the catheter continuously measure ICP. Intraventricular monitoring is especially useful. An intraventricular catheter can be used both to monitor ICP and to reduce this pressure when it is too high by intermittently extracting excess cerebrospinal fluid. Intraparenchymal and intraventricular monitoring are gold standards of ICP measurement. However, the procedures required to measure ICP with these methods are invasive. They require opening the skull and carry risks such as bleeding, infection, and damage to brain tissue. Present Study. The researchers propose use of an alternative noninvasive ICP monitoring system. They describe the HS-1000 device (HeadSense Medical, Ltd), which emits 6-second-long bursts of sound (66 dB) near one ear. The acoustic signals pass throughout the cranium and, along with physiological brain sounds, are detected by receiving sensors located in the opposite ear. Advanced signal analysis algorithms are used to evaluate properties of the acoustic signals to determine ICP values. Data corresponding to the 6-second epoch are recorded and displayed on the device monitor. The HS-1000 monitoring system can be used continuously, with repeated 6-second epochs, to maintain a constant evaluation of ICP. The researchers tested the new noninvasive ICP monitoring tool in 14 patients receiving treatment for traumatic brain injury and/or subarachnoid hemorrhage in an intensive care unit. Invasive intraventricular or intraparenchymal monitoring of the patients’ conditions was already in place. The researchers then compared ICP values obtained using the noninvasive HS-1000 device with ICP values obtained using an invasive (intraventricular or intraparenchymal) monitoring system. A comparison of 2543 data points of continuous ICP monitoring showed a strong association between ICP values obtained using noninvasive and invasive methods. Differences in mean ICP values were +/- 3 mm Hg in 63 percent of data-paired readings and +/- 5 mm Hg in 85 percent of data-paired readings. The authors point out that similar differences have been found in studies comparing the two invasive methods (intraventricular and intraparenchymal). The sensitivity and specificity of noninvasive ICP monitoring were determined to be 0.7541 and 0.8887, respectively. Overall, the findings show a good correlation between ICP values obtained using noninvasive and invasive methods of monitoring. Although this study is preliminary and further investigation is warranted, the authors show that the HS-1000 ICP system provides useful information on normal and elevated ICP values. The authors suggest that use of the device could protect patients from infection and hemorrhage—potential risks of invasive ICP monitoring–and also could aid clinicians in deciding when invasive ICP monitoring may be appropriate. When asked about the study, Dr. Ganslandt said, “The first results look promising, but further refinements in the algorithm will be necessary to allow a reliable clinical application.” Find more information on the study here.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !